Chapter 5 Function Code Table
- 43 -
Group F0: Basic Parameters Group F7: Distance Control Parameters
Group F1: Motor Parameters Group F8: Auxiliary Parameters
Group F2: Performance Control Parameters
Group F9: Input and Output Function
Parameters
Group F3: Door Open Running Curve Parameters Group FA: Display and Fault Parameters
Group F4: Door Close Running Curve Parameters Group FF: Factory Parameters (Reserved)
Group F5: Door Open/Close Auxiliary Parameters Group FP: User Parameters
Group F6: Distance Control Parameters
Function
Code
Parameter Name Setting Range Default
Min.
Unit
Property
Group F0: Basic Parameters
F0-00 Control mode
0: Sensorless vector control
(SVC)
1: Closed-loop vector control
(CLVC)
1 1
★
F0-01
Door open/close mode
selection
0: Speed control
1: Distance control
1 1
★
F0-02 Command source selection
0: Operation panel control
1: Door machine terminal
control
2: Door machine manual
control
3: Door machine auto
demonstration
0 1
★
F0-04
Running frequency under
operation panel control
0.00 to F1-04 5.00 Hz
0.01
Hz
☆
F0-05 Input signal quick setting 0–2 1 1
★
F0-06 Speed at low speed running 0.00 to F1-04 4.00 Hz
0.01
Hz
☆
F0-07 Carrier frequency 2.0–16.0 kHz 8.0 kHz 0.1 kHz
☆
Group F1: Motor Parameters
F1-00 Motor type
0: Asynchronous motor
1: PMSM
8.0 kHz 0.1 kHz
★
F1-01 Rated motor power 0–750 W 1 1
★
F1-02 Rated motor voltage 0–250 V
Model
dependent
1 V
★
F1-03 Rated motor current 0.001–9.900 A 100 V 1 V
★
F1-04 Rated motor frequency 1.00–99.00 Hz
Model
dependent
0.001 A
★
F1-05 Rated motor speed 0–9999 RPM 24.00 Hz
0.01
Hz
★