Chapter 5 Function Code Table
- 51 -
Function
Code
Parameter Name Setting Range Default
Min.
Unit
Property
Group FA: Display and Fault Parameters
FA-00 Display in running state 1–511 319 1
☆
FA-01 Display in stop state 1–63 39 1
☆
FA-02 1st fault type 0–30 0 1
●
FA-03 1st fault prompt 0–9 0 1
●
FA-04 2nd fault type 0–30 0 1
●
FA-05 2nd fault prompt 0–9 0 1
●
FA-06 3rd fault type 0–30 0 1
●
FA-07 3rd fault prompt 0–9 0 1
●
FA-08 4th fault type 0–30 0 1
●
FA-09 4th fault prompt 0–9 0 1
●
FA-10 5th fault type 0–30 0 1
●
FA-11 5th fault prompt 0–9 0 1
●
FA-12 Bus voltage upon latest fault 0–999.9 V 0 V 0.1 V
●
FA-13
Output current upon latest
fault
0–99.00 A 0.00 A 0.01 A
●
FA-14
Running frequency upon
latest fault
0–99.00 Hz 0.00 Hz
0.01
Hz
●
FA-15
Output torque upon latest
fault
0.0–180.0% (percentage
of output torque to rated
torque)
0.0% 0.1%
●
FA-16
Input terminal status upon
latest fault
0–1023 0 1
●
FA-17
Output terminal status upon
latest fault
0–15 0 1
●
FA-18 Terminal state display * * *
●
FA-19 Input signal display * * *
●
FA-20 Output signal display * * *
●
FA-21 Parameter display selection 0–9999 0 1
☆
FA-22 Display 1 0–9999 0 1
●
FA-23 Display 2 0–9999 0 1
●
FA-24 Analog voltage display 0.00–10.10 V 0.00 V 0.01 V
●
FA-25
Low bit of current door
position
0–9999 0 1
●
FA-26
High bit of current door
position
0–9999 0 1
●
FA-27 Door machine state display 0–9999 0 1
●
FA-28 Door direction judgment * * *
●