Intel® Server Board S1200SP Family Technical Product Specification
89
Note: System Fans will boost and the BIOS Error Manager should report an 84F3 error code
(Baseboard Management Controller in update mode).
5. Boot to the EFI shell and update the BMC firmware using BMC####.NSH (where #### is the version
number of the BMC).
6. When update has successfully completed, power off system.
7. Remove AC power cords.
8. Move BMC FRC UPDT jumper back to the default position.
9. Install AC power cords.
10. Power on system.
11. Boot to the EFI shell and update the FRU and SDR data using FRUSDR####.nsh (where #### is the
version number of the FRUSDR package).
12. Reboot the system.
13. Configure desired BMC configuration settings.