System Event Log Troubleshooting Guide for EPSD
 
Platforms Based on Intel
®
 Xeon
®
 Processor E5 4600/2600/2400/1600/1400 Product Families 
Miscellaneous Events 
Revision 1.1  Intel order number G90620-002  103 
11.2.1  SMI Timeout – Next Steps 
This event normally only occurs after another more critical event. 
1.  Check the SEL for any critical interrupts, memory errors, bus errors, PCI errors, or any other serious errors. 
2.  If these are not present, the system locked up before it was able to log the original issue. In this case, low level debug is normally 
required. 
11.3  System Event Log Cleared 
The BMC logs a SEL clear event. This is only ever the first event in the SEL. Cause of this event is either a manual SEL clear using 
selview or some other IPMI-aware utility, or is done in the factory as one of the last steps in the manufacturing process. 
This is an informational event only. 
Table 80: System Event Log Cleared Sensor Typical Characteristics 
10h = Event Logging Disabled 
Event Direction and 
Event Type 
[7] Event direction 
0b = Assertion Event 
1b = Deassertion Event 
[6:0] Event Type = 6Fh (Sensor Specific) 
[7:6] – 00b = Unspecified Event Data 2 
[5:4] – 00b = Unspecified Event Data 3 
[3:0] – Event Trigger Offset = 2h = Log area reset/cleared