System Event Log Troubleshooting Guide for EPSD
 
Platforms Based on Intel
®
 Xeon
®
 Processor E5 4600/2600/2400/1600/1400 Product Families 
Cooling Subsystem 
Revision 1.1  Intel order number G90620-002  47 
[7:6] – 00b = Unspecified Event Data 2 
[5:4] – 00b = Unspecified Event Data 3 
[3:0] – Event Trigger Offset as described in Table 32 
The following table describes the severity of each of the event triggers for both assertion and deassertion. 
Table 32: Fan Presence Sensors – Event Trigger Offset – Next Steps 
Assertion –A fan was inserted. This 
event may also get logged when the 
BMC initializes when AC is applied. 
Deassert – A fan was removed, or 
was not present at the expected 
location when the BMC initialized. 
These events only get generated in the systems with hot-swappable fans, 
and normally only when a fan is physically inserted or removed. If fans 
were not physically removed: 
1.  Use the Quick Start Guide to check whether the right fan 
headers were used. 
2.  Swap the fans round to see whether the problem stays with the 
location or follows the fan. 
3.  Replace the fan or fan wiring/housing depending on the outcome 
of step 2. 
4.  Ensure the latest FRUSDR update has been run and the correct 
chassis is detected or selected. 