Chapter 6: Command line mode
NS3552-8P-2S-V2 User Manual 361
Security Switch SNMP Trap Link-up
Description:
Set or show the port link-up and link-down trap mode.
Syntax:
Security Switch SNMP Trap Link-up [enable|disable]
Parameters:
enable : Enable SNMP trap link-up and link-down
disable: Disable SNMP trap link-up and link-down
(default: Show SNMP trap link-up and link-down mode)
Default Setting:
enable
Example:
Disable SNMP trap link-up
NS3552
-8P-2S-V2:/>
security
switch
snmp
trap link-up disable
Security Switch SNMP Trap Inform Mode
Description:
Set or show the SNMP trap inform mode.
Syntax:
Security Switch SNMP Trap Inform Mode [enable|disable]
Parameters:
enable : Enable SNMP trap inform
disable: Disable SNMP trap inform
(default: Show SNMP inform mode)
Default Setting:
enable
Example:
Disable SNMP trap inform mode.
NS3552
-8P-2S-V2:/>
security
switch
snmp
trap inform mode disable
Security Switch SNMP Trap Inform Timeout
Description:
Set or show the SNMP trap inform timeout (usecs).
Syntax:
Security Switch SNMP Trap Inform Timeout [<timeout>]
Parameters:
<timeout>: SNMP trap inform timeout (0-2147 seconds)
(default: Show SNMP trap inform timeout)
Default Setting:
1
Example:
Set SNMP trap inform timeout in 20sec.
NS3552
-8P-2S-V2:/>
security
switch
snmp
trap inform timeout 20