Chapter 6: Command line mode
480 NS3552-8P-2S-V2 User Manual
DIDO DO Enable
Description:
Set or show the system digital output0/1.
Syntax:
DIDO Do_en [first|second] [enable|disable] [hightolow|lowtohigh]
Parameters:
first : Digital Input/Output 0
second : Digital Input/Output 1
(default: Set or show digital input/output first(0)/second(1) select)
enable : Enable digital input0/1 function
disable : Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)
hightolow : Trigger -> high to low
lowtohigh : Trigger -> low to high
(default: Set or show digital input/output 0/1 trigger)
DIDO DO Port Alarm
Description:
Set or show the system digital output0/1 port alarm.
Syntax:
DIDO Do_port_alr [first|second] [<port_list>]
Parameters:
first : Digital Input/Output 0
second : Digital Input/Output 1
(default: Set or show digital input/output first(0)/second(1) select)
<port_list>: Port list or 'all', default: All ports
DIDO DO Power Alarm
Description:
Set or show the system digital output0/1 power alarm.
Syntax:
DIDO Do_pwr_alr [first|second] [dc1|dc2] [enable|disable]
Parameters:
first : Digital Input/Output 0
second : Digital Input/Output 1
(default: Set or show digital input/output first(0)/second(1) select)
dc1 : DC power 1
dc2 : DC power 2
(default: Set or show digital output/fault alarm 0/1 power_fail)
enable : Enable digital input0/1 function
disable : Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)
DIDO Fault Act
Description:
Set or show the system fault alarm action.
Syntax:
DIDO Fault_act [port|power] [enable|disable]