ZeroWire Installation Manual 95
Connecting Outputs
ZeroWire has two general purpose outputs located on the rear of the unit. These can be
connected to up to 2 devices. Use the supplied header cable.
Input/Output
Connector
1. Ground
2. Input 1
3. Input 2
4. Output 1
5. Output 2
6. 8.5V+
Pin Outs
Outputs are controlled by Actions in the ZeroWire.
When an output is configured with an action, the output will monitor the status of the
action:
When the action logic is true, the output will be on
When the action is false, the output will be off
If no action is assigned to an output the default behaviour is:
Output 1 = Siren
Output 2 = Strobe
To program outputs from ZeroWire Web Server:
1. Click Advanced Actions
2. Create an Action refer to ZeroWire Reference Guide for more help
3. Click Advanced Devices System Devices Control
4. Click “Control Output 1” or “Control Output 2”
Input/Output
Connector
Pins
1.
Ground
2. Input 1
3. Input 2
4. Output 1
5. Output 2
6. 8.5 V+