28 ZSim Programmer’s Guide
Line Analyzer
Purpose: Determines whether to print received data on
the label.
Default: Off
Log to Card
Purpose: Logs the received data to a file on a
CompactFlash card. You can use the log file for
later analysis. This feature is not supported on
the PB50.
Default: Off
LTS
Purpose: Turns the label taken sensor (LTS) on or off.
Default: Off
Media Contrast
Purpose: Adjusts the darkness and contrast of the
printout. You can adjust this value from 0 to 30.
Has influence only on the Fingerprint setup
parameter “Contrast.” A value of 15
corresponds to the Fingerprint contrast value
0%.
Default: 15 (0% in Fingerprint)
Media Type
Purpose: Sets the type of media used in the printer.
Choices include: Continuous, Non-continuous
with Mark, or Non-continuous with Gap.
Terms that appear in the Media Type command
are Zebra-specific. Use the following table to
understand how to select the correct media type.
Zebra-Specific Intermec Printer
Non continuous web Label with gaps
Non continuous mark Ticket with marks
Continuous Fixed length strip