Invacare®TDX®SP2Series
qCablesshallbeinspectedperiodicallytoensure
thattheyareroutedandsecuredproperly.Periodic
inspectionisrecommendedasitmayrevealloose
and/ordamagedcables.Re-secureallloosecablesand
replacebyfollowingtherecommendationsoutlinedin
theLiNXControlsSystemServiceManual.
qEnsureproperoperationofpoweredfunctions(drive,
seating,legrests,etc.).
qInspectgearboxcoupling.
qInspectelectricalcomponentsforsignsofcorrosion.
Replaceifcorrodedordamaged.
qInspectbatteryterminalsforloosecableconnection.
Tightenifnecessary.
qEnsureswingarmstopsareinplaceandnotdeteriorated
ordamaged.Replaceifnecessary.
qCleanupholsteryandarmrests.
qCleandirtandlintfromaxles.
qCleandirtandlintfrombearings.
qCheckthatalllabelsarepresentandlegible.Replace
ifnecessary.
qEnsureclothingguardsaresecure.
qEnsureupholsterydoesnothaveanyripsortears.
qEnsurearmrestpadsitsushagainstarmtube.
qEnsurewheelchairrollsstraight(noexcessivedragor
pulltooneside).
qEnsurethatthecastersarefreeofdebris.
qInspectallfastenersincludingthebackpan,backcane
andangleadjustmentfasteners,andthearmsupport,
ipbackandheightadjustmentfasteners.Ensure
fastenersaresecurelytightened.
qInspectTRBKTSfastenersandhardware.
qInspectfoamhandgripsfordamage.Ifdamaged,have
themreplacedbyaqualiedtechnician.
9.3.2ReplaceEvery18Months
Replacegearboxcoupling.
9.3.3ReplaceEvery2Years
ThestabilitylockingcylindersMUSTbereplacedeverytwo
years.
9.4Cleaning
WARNING!
RiskofInjury,DamageorDeath
Electricalshockmaycauseinjury,damageor
death.
–Alwaysunplugtheproductfromtheelectrical
outletbeforecleaning.
–Alwaysunplugaccessoriesfromtheelectrical
outletbeforecleaning.
CAUTION!
RiskofDamage
Cleaningormaintenancemaycausedamageto
carpetingorooring.
–Placethewheelchairinawellventilated
areawherecleaningormaintenancecanbe
performedwithoutriskofdamagetocarpeting
orooring.
6860101831-A