Invacare®TDX®SP2Series
7.2.4HowtoDisconnecttheMobilityDeviceAfter
Charging
1.Oncechargingiscomplete,disconnectthebattery
chargerfromthepowersupply.
2.Disconnecttheplugfromtheremote.
7.2.5StorageandMaintenance
Followtheinstructionslistedbelowtoensuresafeuseand
longevityofthebatteries:
•Alwaysstorethebatteriesfullycharged.
•Donotleavethebatteriesinalowstateofcharge
foranextendedlengthoftime.Chargeadischarged
batteryassoonaspossible.
•Incaseyourmobilitydeviceisnotusedforalonger
periodoftime(thatismorethantwoweeks),the
batteriesmustbechargedatleastonceamonthto
maintainafullchargeandalwaysbechargedbefore
use.
•Avoidhotandcoldextremeswhenstoring.We
recommendtostorebatteriesatatemperatureof
59°F(15°C).
•GelandAGMbatteriesaremaintenance-free.Any
performanceissuesshouldbehandledbyaproperly
trainedmobilitydevicetechnician.
7.2.6UsingtheProperBatteries
WARNING!
RiskofInjuryorDamage
Impropercongurationofbatteryterminalsmay
causeinjuryordamage.
–Batterieswithterminalcongurationasshown
MUSTbeused.
–TerminalsMUSThaveacrossholeinthemas
shown.
–ThePOSITIVE(+)REDbatterycableMUST
connecttothePOSITIVE(+)battery
terminals/posts.
–TheNEGATIVE(-)BLACKbatterycable
MUSTconnecttotheNEGATIVE(-)battery
terminals/posts.
–DONOTallowanyofyourtoolsand/orbattery
cablestocontactbothbatteryterminalsatthe
sametime.
CAUTION!
RiskofDamage
Useofwrongbatterytypeorsizemaycause
damage.
–DONOTforceabatteryintoplace.
–Batterieswithmoldedstrapsorangesthat
interferewithproperbatteryplacementshould
notbeused.
–Usebatterieslistedinthismanualforproper
replacement.
4660101831-A