BPD series PV pumping inverter Function parameters
31
Function
code
Name
Detailed description
Default
Modify
P05.09
HDI terminals
function
selection
12: Cancel the frequency change setting
13: Shift between A setting and B setting
14: Shift between combination setting and A
setting
15: Shift between combination setting and B
setting
16: Multi-step speed terminal 1
17: Multi-step speed terminal 2
18: Multi-step speed terminal 3
19: Multi- stage speed terminal 4
20: Multi- stage speed pause
21: ACC/DEC time 1
22: ACC/DEC time 2
23: Simple PLC stop reset
24: Simple PLC pause
25: PID control pause
26: Traverse Pause(stop at the current frequency)
27: Traverse reset(return to the center frequency)
28: Counter reset
29: Torque control prohibition
30: ACC/DEC prohibition
31: Counter trigger
32: Reserve
33: Cancel the frequency change setting
temporarily
34: DC brake
35: Reserved
36: Shift the command to the keypad
37: Shift the command to the terminals
38: Shift the command to the communication
39: Pre-magnetized command
40: Clear the power
41: Keep the power
42: PV disabled
43: PV voltage reference
0