BPD series PV pumping inverter    Function parameters 
45 
For models of 220V, the default value is 330.0V, 
and for models of 380V, the default value is 
570.0V. 
Setting range: 220.0V–600.0V 
Device 
configuration 
display 
0: PV power supply   
1: AC grid power supply 
Displaying the most significant 16 bits of the total 
flow of the pump. Unit: m
3
 
Displaying the least significant 16 bits of the total 
flow of the pump. Unit: m
3 
Total flow of pump = P18.13 x 65535 + P18.14 
When P18.15 is set to 1, the total flow of the pump 
is reset, and P18.13 and P18.14 are reset to zero 
to re-calculate the flow. After the reset, P18.15 is 
automatically modified to 0. 
It is used to set the reference voltage of the bus 
when PV input is adopted. 
For models of 220V, the default value is 330.0V, 
and for models of 380V, the default value is 
570.0V. 
Setting range: 220.0V–600.0V