Goodrive270 series VFD for fan and pump Function parameter list
-187-
Function
code
Name Description Default
Modify
P10.08
Multi-step speed 3
When si
mple PLC run is selected, set P10.02±
P10.33
to determine the running frequency and
running time of each step.
Note: The symbol of multi
-step speed
determines the running direction of simple
PLC, and
the negative value means reverse
run
.
P10.02
P10.04
P10.06
P10.32
P10.30
P10.28
Deceleration time
(two sections)
Acceleration time
(two sections)
P10.03 P10.05 P10.07 P10.31 P10.33
When selecting multi
-step speed run, the
multi
-step speed is within -fmax±
fmax, and it can
be set continuously. The start/stop of multi
-step
run
is also determined by P00.01.
The VFD supports the setting of 16
-step speeds
,
which are set by combin
ation of multi-step
terminals 1
±4 (set by S terminal function
s
election, corresponding to function codes
P05.01
±P05.06) and correspond to multi-step
speed 0 to multi
-step speed 15.
Output frequency
t
t
t
t
t
S1
S2
S3
S4
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ON ON ON ON ON
ON
ON ON ON
ON ON ON
ON
ON
ON
When terminal
s 1±
4 are OFF, the frequency input
mode is set by
P00.06 or P00.07
. When terminal
1, terminal 2, terminal 3 and terminal 4 are not all
OFF, the frequency set by multi
-step speed will
prevail, and the priority of multi-step setting is
0.0%
ƻ
P10.09
Run time of step 3
0.0s (min)
ƻ
P10.10
Multi-step speed 4
0.0%
ƻ
P10.11
Run time of step 4
0.0s (min)
ƻ
P10.12
Multi-step speed 5
0.0%
ƻ
P10.13
Run time of step 5
0.0s (min)
ƻ
P10.14
Multi-step speed 6
0.0%
ƻ
P10.15
Run time of step 6
0.0s (min)
ƻ
P10.16
Multi-step speed 7
0.0%
ƻ
P10.17
Run time of step 7
0.0s (min)
ƻ
P10.18
Multi-step speed 8
0.0%
ƻ
P10.19
Run time of step 8
0.0s (min)
ƻ
P10.20
Multi-step speed 9
0.0%
ƻ
P10.21
Run time of step 9
0.0s (min)
ƻ
P10.22
Multi-step speed 10
0.0%
ƻ
P10.23
Run time of step 10
0.0s (min)
ƻ
P10.24
Multi-step speed 11
0.0%
ƻ
P10.25
Run time of step 11
0.0s (min)
ƻ
P10.26
Multi-step speed 12
0.0%
ƻ
P10.27
Run time of step 12
0.0s (min)
ƻ
P10.28
Multi-step speed 13
0.0%
ƻ
P10.29
Run time of step 13
0.0s (min)
ƻ
P10.30
Multi-step speed 14
0.0%
ƻ
P10.31
Run time of step 14
0.0s (min)
ƻ
P10.32
Multi-step speed 15
0.0%
ƻ
P10.33 Run time of step 15
0.0s (min)
ƻ