EasyManua.ls Logo

INVT GD270-090-4 - P15 Group Communication Expansion Card 1 Functions

INVT GD270-090-4
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive270 series VFD for fan and pump Function parameter list
-206-
Function
code
Name Description Default
Modify
communication
-based control mode)
3: Stop according to the stop mode without
generating alarms (in all control modes)
P14.06
Communication
processing action
0x00
±0x11
Ones place:
0: Respond to write operations
1: Not respond to write operations
Tens place:
0: Password protection is invalid.
1: Password protection is valid.
0x00 ƻ
P14.07±
P14.09
Reserved
P14.10 Remote upgrade
0: Disable
1: Enable
0 Ƽ
P14.11
Remote upgrade
software version
0
±655.35 ƽ
P14.12±
P14.24
Reserved
P15 group²Communication expansion card 1 functions
Function
code
Name Description Default
Modify
P15.00±
P15.27
See the communication
expansion card operation manual for details.
P15.28
Master/slave CAN
communication
address
0
±127 1 Ƽ
P15.29
Master/slave CAN
communication baud
rate
0: 50Kbps
1: 100Kbps
2: 125Kbps
3: 250Kbps
4: 500Kbps
5: 1M bps
2 Ƽ
P15.30
Master/slave CAN
communication
timeout period
0.0 (Invalid)
±300.0s 0.0s ƻ
P15.31±
P15.69
See the communication
expansion card operation manual for details.

Table of Contents