EasyManua.ls Logo

INVT GD270-090-4 User Manual

INVT GD270-090-4
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the INVT GD270-090-4 and is the answer not in the manual?

INVT GD270-090-4 Specifications

General IconGeneral
BrandINVT
ModelGD270-090-4
CategoryWater Pump
LanguageEnglish

Summary

1 Safety precautions

1.4 Safety guidelines

Provides general rules for safe operation, installation, and maintenance.

1.4.1 Delivery and installation

Covers precautions for VFD delivery and installation to prevent damage and injury.

1.4.2 Commissioning and running

Details safety precautions during VFD commissioning and operation.

1.4.3 Maintenance and component replacement

Outlines safety measures for VFD maintenance and component handling.

2 Quick startup

2.6 Basic commissioning

Outlines the basic commissioning steps for the VFD before actual use.

3 Product overview

4 Installation guidelines

4.2 Mechanical installation

Covers the mechanical aspects of VFD installation, including environmental requirements.

4.2.1 Installation environment

Details the essential environmental conditions for optimal VFD performance and longevity.

4.2.8 In-cabinet installation

Discusses VFD mounting within cabinets, considering heat dissipation.

4.3 Standard wiring of the main circuit

Shows the main circuit wiring diagram for AC 3PH 380V VFD models.

4.4 Standard wiring of the control circuit

Provides a wiring diagram for the basic control circuit of the VFD.

4.5 Wiring protection

Covers methods for protecting the VFD, input power cable, and motor against short circuits and thermal overload.

5 Basic operation guidelines

5.5.2 Common commissioning procedure

Provides a step-by-step flowchart for the common commissioning process of the VFD.

5.5.3 Vector control

Explains the integrated sensor-less vector control algorithm for driving AMs and SMs.

5.5.4 Space voltage vector control mode

Discusses the built-in space voltage vector control function and V/F curve modes.

5.5.7 Start/stop control

Explains the three states of VFD start/stop control and the three start modes.

5.5.8 Frequency setting

Describes the VFD's support for multiple frequency reference modes (main and auxiliary channels).

5.5.13 Simple PLC

Introduces the Simple PLC function for multi-step speed control and automatic frequency/direction changes.

5.5.15 PID control

Explains PID control principles and provides a schematic block diagram for output frequency regulation.

5.5.15.1 General procedures for PID parameter setup

Guides on determining proportional gain (P), integral time (Ti), and derivative time (Td).

5.5.20 Fault handling

Provides information on handling VFD faults, including finding causes and solutions.

6 Function parameter list

P01 group—Start and stop control

Details parameters for start modes, frequency settings, and ACC/DEC modes.

P02 group—Parameters of motor 1

Lists parameters for configuring Motor 1, including type, ratings, and protection settings.

P03 group—Vector control of motor 1

Details parameters for vector control of motor 1, including speed-loop and current-loop settings.

P04 group—V/F control

Covers V/F curve settings, torque boost, and oscillation control for motors.

P05 group—Input terminals

Lists parameters related to digital and analog input terminals, including HDI input.

P08 group—Enhanced functions

Lists enhanced functions like jump frequency, carrier frequency, and fault protection selections.

P11 group—Protection parameters

Details various protection parameters for VFD and motor safety.

P10 group—Simple PLC and multi-step speed control

Covers parameters for Simple PLC and multi-step speed control functions.

P12 group—Parameters of motor 2

Lists parameters for configuring Motor 2, similar to Motor 1 configuration.

P23 group—Vector control of motor 2

Details parameters for vector control of motor 2, mirroring motor 1 settings.

P90 group—PID1 control

Details parameters for PID1 control, including reference source, feedback, and tuning parameters.

7 Troubleshooting

7.5 Faults and solutions

Lists common fault codes, their possible causes, and recommended solutions.

7.6 Analysis on common faults

Offers troubleshooting flowcharts for common motor and VFD faults.

7.7 Countermeasures on common interference

Discusses common interference phenomena and their solutions.

8 Maintenance

9 Communication

9.3 Application of Modbus

Explains Modbus RTU mode and RS485 interface usage for VFD communication.

Related product manuals