Goodrive200A inverters Function parameters
40
Function
code
Name Detailed instruction of parameters
Default
value
0: Disable
1: Enable, if the starting need is met, the inverter
will run automatically after waiting for the time
defined by P01.22.
P01.22
The waiting
time of
restart after
power off
The function determines the waiting time before
the automatic running of the inverter when
powering off and then powering on.
Setting range: 0.0~3600.0s
(valid when P01.21=1)
1.0s ○
P01.23
Start delay
time
The function determines the brake release after
the running command is reference, and the
inverter is in a stand-by state and wait for the
delay time set by P01.23
Setting range: 0.0~60.0s
0.0s ○
P01.24
the stop
speed
Setting range: 0.0~100.0 s
0.0s ●
P01.25
0: Output without voltage
1: Output with voltage
2: Output at the DC braking current
0
●
P02 Group Motor 1
P02.01
0.1~3000.0kW
Depend
on
model
Rated
frequency of
AM 1
0.01Hz~P00.03(the Max. frequency)
50.00
1~36000rpm
Depend
on
model
Rated
voltage of
AM 1
0~1200V
Depend
on
model