Goodrive200A inverters Function parameters
40
Function
code
Name Detailed instruction of parameters
Default
value
Modify
0: Disable
1: Enable, if the starting need is met, the inverter
will run automatically after waiting for the time
defined by P01.22.
P01.22
The waiting
time of
restart after
power off
The function determines the waiting time before
the automatic running of the inverter when
powering off and then powering on.
Setting range: 0.0~3600.0s
(valid when P01.21=1)
1.0s
P01.23
Start delay
time
The function determines the brake release after
the running command is reference, and the
inverter is in a stand-by state and wait for the
delay time set by P01.23
Setting range: 0.0~60.0s
0.0s
P01.24
D
elay time of
the stop
speed
Setting range: 0.0~100.0 s
0.0s
P01.25
0Hz output
selection
0: Output without voltage
1: Output with voltage
2: Output at the DC braking current
0
P02 Group Motor 1
P02.01
R
ated power
of AM 1
0.1~3000.0kW
Depend
on
model
P02.02
Rated
frequency of
AM 1
0.01Hz~P00.03(the Max. frequency)
50.00
Hz
P02.03
R
ated speed
of AM 1
1~36000rpm
Depend
on
model
P02.04
Rated
voltage of
AM 1
0~1200V
Depend
on
model

Table of Contents