Goodrive200A inverters Function parameters
65
Function
code
Name Detailed instruction of parameters
Default
value
Modify
code 2
P07.23
Factory bar
code 3
0x0000~0xFFFF
P07.24
Factory bar
code 4
0x0000~0xFFFF
P07.25
Factory bar
code 5
0x0000~0xFFFF
P07.26
Factory bar
code 6
0x0000~0xFFFF
P07.27
Current fault
type
0:No fault
1:IGBT U phase protection(OUt1)
2:IGBT V phase protection(OUt2)
3:IGBT W phase protection(OUt3)
4:OC1
5:OC2
6:OC3
7:OV1
8:OV2
9:OV3
10:UV
11:Motor overload(OL1)
12:The inverter overload(OL2)
13:Input side phase loss(SPI)
14:Output side phase loss(SPO)
15:Overheat of the rectifier module(OH1)
16:Overheat fault of the inverter module(OH2)
17:External fault(EF)
18:485 communication fault(CE)
19:Current detection fault(ItE)
20:Motor antotune fault(tE)
21:EEPROM operation fault(EEP)
22:PID response offline fault(PIDE)
23:Braking unit fault(bCE)
24:Running time arrival(END)
25:Electrical overload(OL3)
26:Panel communication fault(PCE)
27:Parameter uploading fault (UPE)
28:Parameter downloading fault(DNE)
32:Grounding short circuit fault 1(ETH1)
33:Grounding short circuit fault 2(ETH2)
P07.28
Previous fault
type
P07.29
Previous 2
fault type
P07.30
Previous 3
fault type