Goodrive18 series two-in-one VFD Communication
-125-
ASCII master command (from the master
to the VFD)
ASCII slave response (from the VFD to the
master)
LRC CHK Lo
‘A’
LRC CHK Lo
‘A’
END Hi
CR
END Hi
CR
END Lo
LF
END Lo
LF
7.3.2.4 Command code 10H, continuous writing
Command code 10H means that the master writes data to the VFD while the number of data
pieces depends on the "data count" in the command code. A maximum of 16 pieces of data
can be continuously written.
For example, to write 5000 (1388H) to 0004H and 50 (0032H) to 0005H of the VFD whose
slave address is 02H, the frame structure is as follows:
ASCII master command (from the master
to the VFD)
ASCII slave response (from the VFD to the
master)
START
‘:’
START
‘:’
ADDR
‘0’
ADDR
‘0’
‘2’
‘2’
CMD
1
CMD
1
0
0
MSB of data writing
address
‘0’
MSB of data writing
address
‘0’
‘0’
‘0’
LSB of data writing
address
‘0’
LSB of data writing
address
‘0’
‘4’
‘4’
Data count MSB
0
Data count MSB
0
0
0
Data count LSB
0
Data count LSB
0
2
2
Number of bytes
MSB of data in 0004H
0
LRC CHK Hi
E
4
LRC CHK Lo
8
LSB of data in 0004H
MSB of data in 0005H
1
END Hi
CR
3
END Lo
LF
LSB of data in 0005H
Number of bytes
8
/
/
8
/
/
MSB of data in 0004H
LSB of data in 0004H
0
/
/
0
/
/
MSB of data in 0005H
3
/
/
2
/
/

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive18 Series and is the answer not in the manual?

INVT Goodrive18 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive18 Series
CategoryIndustrial Electrical
LanguageEnglish

Related product manuals