SPC Series Solar Pump Inverter Function parameter list
-21-
Function
code
Name
Description
Default
Modify
the upper limit of the running frequency,
the upper limit of the running frequency is
used for running.
Setting range: P00.05P00.03 (Max.
output frequency)
P00.05
Lower limit of
running
frequency
The lower limit of the running frequency
is the lower limit of the output frequency
of the inverter,
When the set frequency is lower than the
lower limit of the running frequency, the
lower limit of the running frequency is
used for running.
Note: Max. output frequency Upper
limit of frequency Lower limit of
frequency
Setting range: 0.00HzP00.04 (Upper
limit of running frequency)
0.00Hz
P00.06
Setting channel
of A frequency
command
0: Keypad
17: Reserved
8: Modbus communication
Setting range: 08
0
P00.10
Frequency set
through keypad
0.00 HzP00.03 (Max. output frequency)
110.00Hz
P00.11
ACC time 1
ACC time means the time needed if the
inverter speeds up from 0Hz to the max.
output frequency (P00.03).
DEC time means the time needed if the
inverter speeds down from the max.
output frequency (P00.03) to 0Hz.
Setting range of P00.11 and P00.12: 0.0
3600.0s
Model
depended
P00.12
DEC time 1
Model
depended
P00.13
Running
direction
0: Run at the default direction. The
inverter runs in forward
direction.(FWD/REV off)
1: Run at the opposite direction. The
inverter runs in reverse direction.
(FWD/REV on)
0