4.2.2 Installation Conditions
(1) The inverter can be installed in an indoor or outdoor environment.
(2) During operation of the inverter, the housing and heat sinks will heat up. Do not install the inverter
where it can be accessed easily.
(3) Do not install the inverter in an area where flammable or explosive materials are stored.
(4) Install the inverter in a well-ventilated environment, so as to facilitate heat radiation.
(5) It is recommended to choose an installation position with shade, or build a sunshade.
Fig. 4.2 Sunshade
(6) Ambient temperature: -30℃~60℃.
(7) The installation position should be far away from electronic devices generating strong
electromagnetic interference.
(8) The installation position should be on a fixed and solid object surface, such as a wall or metal
bracket.
(9) The installation position must provide reliable grounding for the inverter, and the grounding metal
conductor must be made of the same material as the reserved grounding metal conductor of the inverter.
4.3 Space Requirements
(1) Install the inverter at such a height that allows the operator to observe the LED indicator lights of the
inverter easily.