Single Phase Hybrid Inverter Troubleshooting
61
Table 10-1 Fault Codes of Inverter
Check whether the PV panel is connected
properly, damaged, covered with dust, or
blocked by any objects.
Check whether the PV panel is connected
properly, and whether the PV voltage is higher
than the maximum working voltage of the
inverter.
Short circuit of PV panel
Check whether the PV panel is short-circuited.
This fault usually occurs in the early morning.
Please check the cleanliness of the PV panel
surface.
Check whether the PV panel is connected
properly, and whether the PV voltage is higher
than the maximum working voltage of the
inverter.
Over-voltage of hardware
Bus
Restart the inverter. If the fault still exists,
contact your dealer.
Over-current of inverter
hardware
Restart the inverter. If the fault still exists,
contact your dealer.
Over-current of inverter
software
Over-current of boost
hardware
Over-current of boost
software
Auxiliary power hardware
TZ failure
Over-voltage of Bus
hardware TZ
Hardware TZ failure at
LLC side
Over-current of buck-
boost software
Abnormal inverter
temperature
Check the inverter temperature. If the
temperature is too high, cool the inverter down
before use.
Abnormal Boost
temperature