Single Phase Hybrid Inverter                                                                                                                Troubleshooting 
61 
Table 10-1 Fault Codes of Inverter 
Check  whether  the  PV  panel  is  connected 
properly,  damaged,  covered  with  dust,  or 
blocked by any objects. 
Check  whether  the  PV  panel  is  connected 
properly, and whether the PV voltage is higher 
than  the  maximum  working  voltage  of  the 
inverter. 
Short circuit of PV panel 
Check whether the PV panel is short-circuited. 
This fault usually occurs in the early morning. 
Please check  the  cleanliness of  the  PV  panel 
surface. 
Check  whether  the  PV  panel  is  connected 
properly, and whether the PV voltage is higher 
than  the  maximum  working  voltage  of  the 
inverter. 
Over-voltage  of  hardware 
Bus 
Restart  the  inverter.  If  the  fault  still  exists, 
contact your dealer. 
Over-current  of  inverter 
hardware 
Restart  the  inverter.  If  the  fault  still  exists, 
contact your dealer. 
Over-current  of  inverter 
software 
Over-current  of  boost 
hardware 
Over-current  of  boost 
software 
Auxiliary power hardware 
TZ failure 
Over-voltage  of  Bus 
hardware TZ 
Hardware  TZ  failure  at 
LLC side 
Over-current  of  buck-
boost software 
Abnormal  inverter 
temperature 
Check  the  inverter  temperature.  If  the 
temperature is too high, cool the inverter down 
before use. 
Abnormal  Boost 
temperature