15
Pre-programming mode 3
HEAt-SYS = Heating system
On machines with hot water supply, the modulation technique can be used. For this purpose, a controlled
water mixing is applied during water supply, as a result of which the temperature of the bath after loading is
perfect in most cases. If this option is not used, a traditional mixing system is used.
In following steps, you have to enter whether this modulation technique will be used or not.
Therefor, select from the following:
HEAt ( heating system without modulation )
HEAt-Mod ( heating system and modulation )
Mod ( no heating system, only modulation )
If no hot water inlet valves are selected (zee SE-i) " HEAt " is automatically selected and " HEAt-SYS
" will not be displayed.
HECo = execute heating control ( temperature control )
This means stopping the program temporarily during warm up, until the right temperature is reached.
GEntlE = Converting the movement time and the dwell time of the tumbler during temperature control.
If the machine is not equipped with a heating system ( Mod at HEAt-SYS), the functions HECo and
GEntlE will not be displayed.
t $C of t $F = temperature selection in °C or °F.
SoAP = Injection pumps for liquid soap
If no liquid soap supplies are provided, continue with Add
SoAP 01
= Soap pump 1
Soap injection via pump 1
On PS40, a maximum of 12 liquid soap supplies can be connected ( standard 6 + 6 optional).
Select the desired soap supplies from Soap 01 to SoAP 12 inclusive.
SoAP 12
= Soap pump 12