Programming mode 4
dI = Drain 1
Select " d1 ", " d2" , " rd1", " rd2" of " dO"met " NO " and confirm "E ".
When "dO" is selected, the water will not be discharged ( transition to the next program part )
The number of drain valves of which you can choose, is dependent upon the setting of the pre-
program.
dt ((( = Drain time
With " X,X,X " enter the drain time ( max 180 secs ) and press " ENTER ". With " NO " select from
" WASh ", " diSt ", " JoLt" and " DrAin " which action should be performed in between two
discharges and confirm with " ENTER " .
WASh = Washing movement
Washing movement of the drum during water discharge.
diSt = Distribution (distribution speed) (not on machines of the type WE (no HF))
Distribution movement of the drum during water discharge.
Jolt = Short spinning ( after distribution, low spinning for 10 secs )
At " dt ((( " enter a minimum of 60 secs
DrAin = discharge
Water discharge without movement of the drum
t= (((( = Time
This is the duration of the program part.
Press " ENTER ".