Programming mode 4
SoAP= Liquid soap supply
If no soap injection is desired, select " no SoAP " and press " ENTER ". (Transfer to
" (( SE-L ")
If soap injection is desired, select" SoAP " and press " ENTER ".
The program will proceed with the first soap inlet activated in the " pre program " .
Example: "So1" (Soap 1)
SoI = Liquid soap injection 1
Use " NO " to choose whether a soap inlet pump should be selected or not.
Then press " ENTER ".
t1 (((= Time 1 (duration of soap injection 1)
Enter the duration with " X,X,X " ( maximum 999 seconds ).
Press " ENTER " to proceed to the next soap injection.
Depending on the selection in " pre-program " the soap inlets can be programmed one after the other (from So1
to So12 included).
In order to save space, only SO 1 was drawn, the others are identical.
If in Pre - program " AlArm " was selected, " So6 " will not be displayed.
Overflow ( extremely soiled linnen )
- enter " 0$C " (of " $F ") at " ((tEMP "
- select " no HECo " and enter the level " 00 " at " L (( ".
During the complete washing time, water will be supplied and discharged via the overflow.
LECo = Level control
If no level control is desired, select " no LECo " and press " ENTER ".
If level control is desired, select " LECo " and press " ENTER ".
LS (( = Level stop (level control)
With " X,X " enter the level where the program time should stop ( automatically limited ) till the set value is
reached at " LE (( ").
When this level is reached, the programmer continues and the bath is filled till the level set at "L (( " is
reached. Press " ENTER ".
Press " Enter " after setting the soap inlets.
(( SE-L = Select level ( select water level )
Press " ENTER "
LE (( = Level (Water level)
Use " X,X " to enter the level (5 to 50) ( experimental ) and press " ENTER ".
The next step depends on the selection made during " pre-programming "
- without " LECo " ( level control ) : transfer to " Add " (or " no Add ")
- with " LECo " ( level control ): transfer to " LECo " (or " no LECo ")
When , " 0$" is entered at " (( tEMP" , you can enter a level between 0 and 50.