40
´
´
´
´
Operating mode 6
Controlling the program during functioning
By pressing " NO " for longer then 3 seconds and releasing, all set steps per program part are displayed one
after the other during 1second.
By pressing and holding " NO " once more, the step performed last is displayed. After releasing the " NO
", the next steps are given.
At the end of the program part, " EntEr " appears during 3 seconds. In order to proceed with the reading of
the next program part, " ENTER " should be pressed within that time. If not, the normal course of the program
is displayed.
Running through the program quickly
While pressing " " , the program will be accelerated ( if accelerate (" ACCL") was selected in
" pre - program ").
The seconds are counted down faster. The acceleration is interrupted at every major step of the program
( discharge, cool down, etc. ) Press the acceleration key once more to continue more rapidly.
In this way, you have the possibilité not to execute certain parts or the rest of the program.
During tumble, the program cannot be accelerated.
Programmed stop
When a " stop " has been programmed, the program will stop there. The water remains in the drum, there are
no drum movements and " StoP " appears on the display..
After pressing " START ", the program continues
Stop with stop time.
If a stop time has been programmed, " StoPtiME " and the counting down remaining stop time will
alternately appear on the display. After the stop time has expired, the program time will continue automatically.
The machine stops until " START " is pressed again.
Alarm signal.
If an alarm has been programmed, this will be activated at the beginning of the stop. This signal can be stopped
by pressing " START " or " STOP ".
Soaking
If " SoAk " has been programmed, the program will stop there. The bath will be brought to level 25, kept at
the right temperature and every 3 minutes there will be a left - right movement.
The soaking continues till " START " is pressed.
Soaking with soak time.
If a soak time has been programmed, " SoAktiME " and the counting down remaining soak time will appear
alternately on the display. After the soak time has expired, the program time shall continue automatically.
If, during this soak time, the START - key is being pressed, the program will be proceeded immediately.
Alarm signal.
If an alarm has been programmed, this will be activated at the beginning of the soak time. This signal can be
stopped by pressing " START " or " STOP " .