Manual No. 085-3435-07 13/45 IGB/IGX Series (Overseas Specifications) Service Manual
2.2.2 Scale No. Table
Address
110A 110B 111A 111B
Scale No. Specifications
Default Data
0 150kg (0.05kg/0.02kg) Multi Interval 6 C 3 8
1 60kg (0.02kg/0.01kg) Multi Interval 2 B 3 8
2 30kg (0.01kg/0.005kg) Multi Interval B B 3 8
3 15kg (0.005kg/0.002kg) Multi Interval 7 C 3 8
4 6kg (0.002kg/0.001kg) Multi Interval 3 B 3 8
5 6000g (2g/1g) Multi Interval 0 B
B
8
6 3000g (1g/0.5g) Multi Interval 9 B
B
8
7 120kg (0.02kg) 1/6000 Single Range 6 B 2 8
8 60kg (0.01kg) 1/6000 Single Range 2 B 2 8
9 30kg (0.005kg) 1/6000 Single Range B B 2 8
10 15kg (0.002kg) 1/7500 Single Range 7 B 2 8
11 6kg (0.001kg) 1/6000 Single Range 3 B 2 8
12 300kg (0.1kg) 1/3000 Single Range 1 B 2 8
13 150kg (0.05kg) 1/3000 Single Range A 8 2 8
14 60kg (0.02kg) 1/3000 Single Range 6 8 2 8
15 30kg (0.01kg) 1/3000 Single Range 2 8 2 8
16 15kg (0.005kg) 1/3000 Single Range B 8 2 8
17 6kg (0.002kg) 1/3000 Single Range 7 8 2 8
18 6000g (2g) 1/3000 Single Range 4 8 A 8
19 3000g (1g) 1/3000 Single Range 0 8 A 8
20 150kg/60kg (0.05kg/0.02kg) Dual Range 6 C 5 8
21 60kg/30kg (0.02kg/0.01kg) Dual Range 2 B 5 8
22 30kg/15kg (0.01kg/0.005kg) Dual Range B B 5 8
23 15kg/6kg (0.005kg/0.002kg) Dual Range 7 C 5 8
24 6kg/3kg (0.002kg/0.001kg) Dual Range 3 B 5 8
25 6000g/3000 (2g/1g) Dual Range 0 B D 8
26 3000g/1500 (1g/0.5g) Dual Range 9 B D 8
27 150kg/150k (0.1kg/0.05kg Dual Range
Fishery specification
A 8 5 8
28 150kg (0.05kg) 1/3000 Single Range
Body weight specification
A 8 4 2
29 30kg (0.01kg) 1/3000 Single Range
Baby scale specification
2 8 4 2
30 300lb/150kg (1/3000) Multi Interval 6 C 7 8
31 150lb/60kg (1/3000) Multi Interval 2 B 7 8
32 60lb/30kg (1/3000) Multi Interval B B 7 8
33 30lb/15kg (1/3000) Multi Interval 7 C 7 8
34 15lb/6kg (1/3000) Multi Interval 3 B 7 8
99 Individual scale settings - - - -
Note
1. By setting the Scale No., the scale will function according to default data of addresses 110 and
111.
2 The above data determines each specification, so changing the data is prohibited.
3 Data A indicates the upper position of the one-byte data, and B indicates the lower position.
Reference
Ref er enc
Refer to “Weighing Condition Data Table” for data details.