EasyManua.ls Logo

ISHIDA IGB-60 - Scale No. Table

ISHIDA IGB-60
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual No. 085-3435-07 13/45 IGB/IGX Series (Overseas Specifications) Service Manual
2.2.2 Scale No. Table
Address
110A 110B 111A 111B
Scale No. Specifications
Default Data
0 150kg (0.05kg/0.02kg) Multi Interval 6 C 3 8
1 60kg (0.02kg/0.01kg) Multi Interval 2 B 3 8
2 30kg (0.01kg/0.005kg) Multi Interval B B 3 8
3 15kg (0.005kg/0.002kg) Multi Interval 7 C 3 8
4 6kg (0.002kg/0.001kg) Multi Interval 3 B 3 8
5 6000g (2g/1g) Multi Interval 0 B
8
6 3000g (1g/0.5g) Multi Interval 9 B
8
7 120kg (0.02kg) 1/6000 Single Range 6 B 2 8
8 60kg (0.01kg) 1/6000 Single Range 2 B 2 8
9 30kg (0.005kg) 1/6000 Single Range B B 2 8
10 15kg (0.002kg) 1/7500 Single Range 7 B 2 8
11 6kg (0.001kg) 1/6000 Single Range 3 B 2 8
12 300kg (0.1kg) 1/3000 Single Range 1 B 2 8
13 150kg (0.05kg) 1/3000 Single Range A 8 2 8
14 60kg (0.02kg) 1/3000 Single Range 6 8 2 8
15 30kg (0.01kg) 1/3000 Single Range 2 8 2 8
16 15kg (0.005kg) 1/3000 Single Range B 8 2 8
17 6kg (0.002kg) 1/3000 Single Range 7 8 2 8
18 6000g (2g) 1/3000 Single Range 4 8 A 8
19 3000g (1g) 1/3000 Single Range 0 8 A 8
20 150kg/60kg (0.05kg/0.02kg) Dual Range 6 C 5 8
21 60kg/30kg (0.02kg/0.01kg) Dual Range 2 B 5 8
22 30kg/15kg (0.01kg/0.005kg) Dual Range B B 5 8
23 15kg/6kg (0.005kg/0.002kg) Dual Range 7 C 5 8
24 6kg/3kg (0.002kg/0.001kg) Dual Range 3 B 5 8
25 6000g/3000 (2g/1g) Dual Range 0 B D 8
26 3000g/1500 (1g/0.5g) Dual Range 9 B D 8
27 150kg/150k (0.1kg/0.05kg Dual Range
Fishery specification
A 8 5 8
28 150kg (0.05kg) 1/3000 Single Range
Body weight specification
A 8 4 2
29 30kg (0.01kg) 1/3000 Single Range
Baby scale specification
2 8 4 2
30 300lb/150kg (1/3000) Multi Interval 6 C 7 8
31 150lb/60kg (1/3000) Multi Interval 2 B 7 8
32 60lb/30kg (1/3000) Multi Interval B B 7 8
33 30lb/15kg (1/3000) Multi Interval 7 C 7 8
34 15lb/6kg (1/3000) Multi Interval 3 B 7 8
99 Individual scale settings - - - -
Note
1. By setting the Scale No., the scale will function according to default data of addresses 110 and
111.
2 The above data determines each specification, so changing the data is prohibited.
3 Data A indicates the upper position of the one-byte data, and B indicates the lower position.
Reference
Ref er enc
e
Refer to “Weighing Condition Data Table” for data details.

Related product manuals