EasyManuals Logo

ISHIDA IP-EMZ User Manual

ISHIDA IP-EMZ
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
Chapter 1 INSTALLATION
1-10 IP-EMZ Operation Manual
1.7 FINALIZING INSTALLATION
Span check
6kg:
Place the 6kg weight on the weighing platter and confirm that the displayed weight is within ±1d (2g).
15kg:
Place the 15kg weight on the weighing platter and confirm that the displayed weight is within ±1d (5g).
30lb:
Place the 30lb weight on the weighing platter and confirm that the displayed weight is within ±1d
(0.01lb).
Four corner check
6kg:
Place weighs (Approximately 3kg but not heavier) on the center and four corners of the weighing
platter, and confirms that the difference between the center and four corners is within ±1d (1g).
15kg:
Place weighs (Approximately 6kg but not heavier) on the center and four corners of the weighing
platter, and confirms that the difference between the center and four corners is within ±1d (2g).
30lb:
Place weighs (Approximately 15lb but not heavier) on the center and four corners of the weighing
platter, and confirms that the difference between the center and four corners is within ±1d (0.005lb).
Call up a product, place a load on the weighing platter, and issue a label.
After issuing the label, clear the result.
Connect the IF-21FD and save the settings.
Explain the operation method and precautions to the user.
Weighing check
Operation check
Set content save
Operation explanation

Other manuals for ISHIDA IP-EMZ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ISHIDA IP-EMZ and is the answer not in the manual?

ISHIDA IP-EMZ Specifications

General IconGeneral
BrandISHIDA
ModelIP-EMZ
CategoryScales
LanguageEnglish

Related product manuals