EasyManuals Logo
Home>ITech>Power Supply>IT7300 Series

ITech IT7300 Series Programming Guide

ITech IT7300 Series
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
System Commands
Copyright © Itech Electronic Co., Ltd. 15
Query syntax
STATus:QUEStionable:CONDition?
Parameters
None
Returns
<NR1>
STATus:QUEStionable:ENABle<Enable value>
This command edits the enable register value of query event. In query, the
power supply will return a decimal number representing the binary weighted
sum of the enable register.
Command syntax
STATus:QUEStionable:ENABle <NRf>
Parameters
0~65535
Power on value
Refer to *PSC command.
Example
STATus:QUEStionable:ENABle 16
Query syntax
STATus:QUEStionable:ENABle?
Returns
<NR1>
Related commands
*PSC
STATus:QUEStionable:NTRansition
This command set the value of the Questionable NTR (Negative-Transition)
register. The register serve as polarity filters between the Questionable
Condition and Questionable Event registers to cause the following actions.
When a bit of Questionable NTR register is set to 1, then a 1-to-0 transition of
the corresponding bit of the Questionable Condition register causes that bit in
the Questionable Event register to be set.

Table of Contents

Other manuals for ITech IT7300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7300 Series and is the answer not in the manual?

ITech IT7300 Series Specifications

General IconGeneral
BrandITech
ModelIT7300 Series
CategoryPower Supply
LanguageEnglish

Related product manuals