Erreur ! Utilisez l'onglet Accueil pour appliquer Heading 1 au texte que vous souhaitez faire apparaître ici.
7.7.2. Seasons
The meter supports up to twelve seasons per year, for which different tariff regimes can be programmed. These
seasons are defined by start dates, which can be set individually or derived from programmed daylight saving
dates/times.
The start date of the first tariff season is always defined as 1st of January.
The following example illustrates four individually configured seasons:
7.7.3. Week profiles
A week profile is always associated with a season and contains a collection of seven individually-defined day
profiles (Monday through to Sunday).
The following example illustrates individual weekly profiles for five seasons:
7.7.4. Day profiles
Each Day Profile (DP) enables the tariff rate to be changed (switched) up to 16 times over a 24-hour period.
Each tariff rate switch has a pre-configured index (page 30) associated with it and a switching-time resolution of 1
minute.
Up to 24 individual day profiles can be defined with a total usage limit of 100 switching-time operations.
The meter will apply the same day profile every day unless the tariff specifies different profiles for weekends,
special days and different seasons.
The start time of a day profile is always defined as 00:00.
The following example illustrates five daily profiles with seven switching-times:
Note: The numbers in enclosed brackets, e.g. [3], show the associated index.