Page #82 background imageLoading...
Page #82 background image
ACE6000 User Guide
80
RESET_MEASUREMENT_DATA
Reset of measurement data
START_MEASUREMENT
Start measurement
STOP_MEASUREMENT
Stop measurement
START_TRIGGERED_TESTS
Start triggered tests
STOP_TRIGGERED_TESTS
Stop triggered tests
END_OF_DATA_SAVING
End of current data saving
LOAD_PROFILE_RESET
Load profile reset
PASSWORD RESTORATION
Password restoration
INDEX_CLOCK_LOSS
Default clock loss index
SUCCESSFUL COMMUNICATION
Successful communication
Note
Event
Comment
1
PARAMETERS_SAVING
Recorded each time new configuration parameters have
been programmed into the meter.
2
AC_FAIL_APPEARANCE
AC_FAIL_DISAPPEARANCE
Recorded when a micro power failure (<=1 second) is
detected by the meter, at the same time the state of power
supply backup is checked.
3
PWR_FAIL_APPEARANCE
Recorded when the meter cut calculation reaches the
lower threshold, all meter data is then saved.
11.2. Alarm descriptions
The following table contains a list of alarms (these may change due to meter firmware revision):
Non-fatal alarm
Type
Description
WATCHDOG ACTIVITY
Trapped
Watchdog
(see note 1 below)
EXTERNAL CLOCK INCOHERENCE
Trapped
Meter clock programming error
(see note 2 below)
CONFIGURATION INCOHERENCE
Trapped
Incoherence of configuration parameters
(see note 3 below)
NON VOLATILE MEMORY NON FATAL
ERROR
Trapped
Checksum error in Flash memory
(see note 1 below)
PROGRAMMING INCOHERENCE
Trapped
Incoherence of parameters programmed
(see note 4 below)
COVER OPENING
Trapped
Detection of abnormal use of terminal cover
NO INTERNAL CONSUMPTION
Self-healing
No internal energy consumed for more than n days
ZERO SEQUENCE U
Self-healing
ZERO SEQUENCE I
Self-healing
CLOCK LOSS
Self-healing
Incoherence of internal clock after power cut
(see note 5 below)
NEUTRAL LOSS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITRON ACE6000 and is the answer not in the manual?

ITRON ACE6000 Specifications

General IconGeneral
Voltage230V AC
Frequency50/60 Hz
DisplayLCD
CommunicationRS-485
Temperature Range+55°C
Current5A
Frequency Range45Hz to 65Hz
Storage Temperature+70°C
Humidity95% RH (non-condensing)