ACE6000 User Guide
52
Cover opening
The meter detects cover opening events and records the following parameters:
number of cover openings (incremental)
the last 10 cover openings (with time stamp and duration)
The meter detects and records the first cover opening event during a power failure.
Magnetic sensor
The meter detects magnetic attacks and records the following parameters:
number of magnetic attacks (incremental)
total duration of magnetic attacks (not including programmable threshold duration)
the last 10 magnetic sensor events with time stamp and duration
Calibrations history
The meter records the following calibration event parameters:
number of calibrations (incremental)
last calibration date and time
Configurations history
The meter records the following configuration event parameters:
number of objects configured (incremental)
last configuration date
Watchdog activity
The meter detects watchdog events and records the following parameters:
number of watchdog events (incremental)
last watchdog event (with time stamp)
Reading without power (RWP)
The meter records the following RWP event parameters if the RWP option is fitted:
number of RWP sessions (incremental)
total duration of RWP sessions

Table of Contents