On entering either alternate display mode, the LCD is backlit and shows the first parameter in the display
sequence.
Alternate long mode
This mode provides a manual display of pre-selected parameters accessible to the end user.
The ALT annunciator icon will be lit.
Alternate short mode
This mode can only be accessed with the reset button unsealed. Typically, it allows the manual display of pre-
selected parameters accessible only by the utility company.
The ALT annunciator icon will flash.
Display navigation
to advance the display to the next parameter, push the display button once (short push)
to auto-scroll through the parameter sequence, hold down the display button
to exit the mode, either auto-scroll or manually advance the display past the last parameter entry. The
display will then return to the normal mode and the LCD backlight will automatically turn off
After a predefined inactivity time-out period, the meter returns automatically to the normal mode.
Reset pushbutton operation
If the reset button is pushed (long push) in either display mode, one of the following occurs:
if the displayed parameter can be modified by the user, the Set mode is activated
if the displayed parameter cannot be modified by the user and an EOB confirmation has not been selected,
an end of billing event (EOB) event occurs
if the displayed parameter cannot be modified by the user and an EOB confirmation has been selected, the
meter displays the pre-configured EOB confirmation string.
To confirm the EOB event, the reset button must be pushed once (long push) while the confirmation string is
visible.