High temperature. Configuration for a high temperature event enables an automatic shut
off if the high temperature threshold is reached or exceeded.
Note: For more information about high flow and high temperature event configuration, see
the FDM documentation. For document information, see Related documents on page 6.
Integrated 500G communications module
The integrated 500G RF communications module is designed to operate in either Mobile or
OpenWay Riva Network Mode. When the Intelis Gas Meter is operating in Mobile Mode, it
may be read by ChoiceConnect handheld readers, mobile collection, or the Itron Mobile
Radio connected to a user-supplied computer or Bluetooth device. When the meter is
operating in OpenWay Riva Network Mode, it is read by the OpenWay Riva Network. For
compatible Itron reading and programming devices, see the Intelis Gas Meter Technical
Reference Guide (TDC-1805-XXX).
Note: The communication functionality is dependent on the module's firmware version.
Intelis Gas Meter specifications
This section lists the Intelis Gas Meter product specifications.
Specification Specification value
Meter capacity
250 CFH at ½ w.c. / 7.1 m
3
/h @0.125 kPa
Measurement principle Ultrasonic time of flight
Accuracy Class 1 and ±0.5% at room temperature
Meter type Temperature compensated (TC) or non-temperature
compensated (NTC)
Hub center-to-center 6 inches (152.4 mm)
Hub size options
10LT
20LT
30LT
1A/Sprague standard
1-1/4", 1" Pittsburgh
ISO G 1-1/4"
Meter MAOP 5 PSIG (35 kPa)
Valve Actuated swing valve, maximum 0.035 CFH (1 L/H)
leakage rate
LCD displayed units CCF (100 x cubic foot) or cubic meter
LCD resolution
00000.001 CCF (0.1 CF) or 00000.001 m
3
Case Aluminum case with ASA 49 gray powder coat finish
Weight 4.5 lbs (2.0 kg)
Gas type Natural gas Type H, E, L (per EN 437)
Reference gases G20, G21, G23, G25, G26, G27
Intelis Gas Meter
Intelis Gas Meter Installation Guide TDC-1782-002 8
Proprietary and Confidential

Table of Contents

Other manuals for ITRON Intelis

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITRON Intelis and is the answer not in the manual?

ITRON Intelis Specifications

General IconGeneral
BrandITRON
ModelIntelis
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals