12. Verify or enter Test Revs: Index Open, Check, Other settings. Itron recommended
settings are listed.
Open: 6
Check: 2
Other: 0
Note: T
esting has shown acceptable results with settings as low as 4 pulses on open and
1 on check but Itron recommends more pulses to obtain better results.
13. Select the Volume: Index setting. The Volume: Index setting is the recommended
volume per pulse. Itron recommended settings are listed.
Imperial setting: 0.10 cu ft/rev
Metric setting: 0.01 m3/rev
Note: Intelis Gas Meter volume per pulse is in dm3; 10dm3 = 0.01 m3.
14. Verify or enter Flow rates (Air Rate): Open, Check, Other settings. Itron recommended
typical settings are listed. For metric flow rates: choose from the flow rate dropdown list
options. These convert the Imperial (CFH) flow rates to Metric (CMH). The Other flow
rate is not required if the Test Revs: Index-Other is set to 0.
Open: 250
Proving the Intelis Gas Meter
Intelis Gas Meter Installation Guide TDC-1782-002 38
Proprietary and Confidential