4. Meter manufacturer Quiet Mode
• Meter manufacturers can configure the pit module for Quiet Mode after initializing and
direct mounting the pit module in the factory.
• The pit module awakens from Quiet Mode and enters run mode in one of two ways:
1. The pit module detects consumption at the top of the hour (last hourly interval >1 or
<-1).
2. The pit module receives a two-way command (for example, a Read ERT using FDM
software).
OpenWay Riva Water module firmware functionality
This section lists the OpenWay Riva Water module firmware information and lists
functionality by version.
Firmware part
number
Global software
release version
(GSR)
FDM Check
Endpoint
firmware version
Over-the-air
firmware part
number
Firmware
functionality
FWM-1601-004 4.1 1.3.7
• Network
topology
•
IPv6
addressable
• 60 minute
interval data
• Mobile Mode
• Firmware
download
FWM-1602-006 4.5 2.1.10.0 DFW-1602-006
• GSR 4.1
functionality
• 5, 10, 15, 30
minute interval
data
• Extended meter
alarms
• Low battery
alarm
• Restricted
water flow state
Events and alarms
For OpenW
ay Riva Modules reporting in Mobile Mode.
Extended event flag. (retrievable with two-way communication)
About the OpenWay Riva Water Module
OpenWay Riva Water Pit Module Installation Guide TDC-1743-004 8
Proprietary and Confidential