4. Meter manufacturer Quiet Mode
Meter manufacturers can configure the pit module for Quiet Mode after initializing and
direct mounting the pit module in the factory.
The pit module awakens from Quiet Mode and enters run mode in one of two ways:
1. The pit module detects consumption at the top of the hour (last hourly interval >1 or
<-1).
2. The pit module receives a two-way command (for example, a Read ERT using FDM
software).
OpenWay Riva Water module firmware functionality
This section lists the OpenWay Riva Water module firmware information and lists
functionality by version.
Firmware part
number
Global software
release version
(GSR)
FDM Check
Endpoint
firmware version
Over-the-air
firmware part
number
Firmware
functionality
FWM-1601-004 4.1 1.3.7
Network
topology
IPv6
addressable
60 minute
interval data
Mobile Mode
Firmware
download
FWM-1602-006 4.5 2.1.10.0 DFW-1602-006
GSR 4.1
functionality
5, 10, 15, 30
minute interval
data
Extended meter
alarms
Low battery
alarm
Restricted
water flow state
Events and alarms
For OpenW
ay Riva Modules reporting in Mobile Mode.
Extended event flag. (retrievable with two-way communication)
About the OpenWay Riva Water Module
OpenWay Riva Water Pit Module Installation Guide TDC-1743-004 8