14.3.7 pH Acid or Base Feed
From the CHEMLINK pH setup screen, highlight the
ACID/BASE entry. Use the UP and DOWN arrows to
select new entry. Touch SAVE when finished.
▪ DEFAULT - Acid.
▪ ACID - Feeds acid to lower the pH.
▪ BASE - Feeds base material to raise the pH.
ChemLink
m
Menu OneTouch Help Back Status
Photos
Power
Thu January 1, 2009 3:03 PM
ChemLink 1 pH Status
Acid/Base Acid
Next Clean Jan 01
Next Cal Jan
Cal at pH 7.5
Adjust
Page
Down
Page
Up
Save
Orp
pH
14.3.8 pH Next Cleaning
Manually set reminder to clean the pH sensor. Enter
Month, then Year for automatic reminder.
▪ DEFAULT - JAN 01 (essentially OFF)
From the CHEMLINK pH setup screen, highlight the
NEXT CLEAN date. Touch the UP or DOWN arrows to
display numeric keyboard screen.
Using the numeric keyboard, touch clear to erase
existing date. Enter new date in Month/Year format.
Touch ENTER when finished.
ChemLink
om
Menu OneTouch Help Back Status
Photos
Power
ChemLink 1 pH Status
Acid/Base Acid
Next Clean Jan 01
Next Cal Jan
Cal at pH 7.5
Adjust
Page
Down
Page
Up
Save
Orp
pH
ChemLink
om
Menu OneTouch Help Back Status
Photos
Power
7 8 9
4 5 6
1 2 3
0
Clear Enter
Date (mm/dd) 00/00
Next Clean
12/22
Thu January 1, 2009 3:03 PM
Thu January 1, 2009 3:03 PM
14.3.9 pH Next Calibration
Manually set reminder to clean the pH sensor. Enter
Month, then Year for automatic reminder.
▪ DEFAULT - JAN 01 (essentially OFF)
From the CHEMLINK pH setup screen, Highlight the
NEXT CAL date. Touch the UP or DOWN arrows to
display numeric keyboard screen.
Using the numeric keyboard, touch clear to erase
existing date. Enter new date in Month/Year format.
Touch ENTER when finished.
ChemLink
H
m
Menu OneTouch Help Back Status
Photos
Power
ChemLink 1 pH Status
Acid/Base Acid
Next Clean Jan 01
Next Cal Jan
Cal at pH 7.5
Adjust
Page
Down
Page
Up
Save
Orp
pH
ChemLink
m
Menu OneTouch Help Back Status
Photos
Power
7 8 9
4 5 6
1 2 3
0
Clear Enter
Date (mm/dd) 00/00
Next Clean
12/22
Thu January 1, 2009 3:03 PM
Thu January 1, 2009 3:03 PM
14.3.10 pH Calibration
This is calibration for pH reading. You can enter the
actual pH here to adjust sensor reading.
▪ DEFAULT - 7.5
From the CHEMLINK pH setup screen, highlight the
CAL AT PH settings. Use the UP and DOWN arrows to
change this setting. Touch SAVE when finished.
ChemLink
H
m
Menu OneTouch Help Back Status
Photos
Power
Thu January 1, 2009 3:03 PM
ChemLink 1 pH Status
Acid/Base Acid
Next Clean Jan 01
Next Cal Jan
Cal at pH 7.5
Adjust
Page
Down
Page
Up
Save
Orp
pH