EasyManua.ls Logo

Janome JUNO E1030 - Self-Diagnostic Test; Preparation; To Begin; To Enter Self-Diagnostic Mode

Janome JUNO E1030
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
TO ENTER SELF-DIAGNOSTIC MODE:
Preparation:
1.Turnthepowerswitchoff.
2.Movethebobbinwinderspindletotheleft.
3.Raisethefeeddog.
4.Setthespeedcontrollevertotheleft.
5.Removethepresserfootandraisethepresserfootlifter.
6.Turnthehandwheeltowardyoutoraisetheneedletoitshighestposition.
NOTE:
•Becareful:thesewingmachinemaystartrunninginitsownwhileintestmode.
•Turnoffthepowerswitchbeforereplacinganyparts.
•Repeatthediagnostictestuntiltheproblemhasbeenresolved.
To begin:
Turnontheswitch.Ifanyofthefollowingproblemsoccur,taketherecommendedactionsintheorderthey
areshown.
1.Themachinedoesnotrespondwhenthepowerswitchisturnedon:
•Checkeachconnectorconnection.
•Replacetheswitchingregulator(withthemachinesocket).
•ReplacetheprintedcircuitboardA.
2.Thesewingmachinelampdoesnotlightup:
•BesureallconnectorsareconnectedtothecircuitboardLandAproperly(Refertopage23).
•ReplacetheprintedcircuitboardL.
•ReplacetheprintedcircuitboardA.
SELF-DIAGNOSTIC TEST
1. Turnthepowerswitchonwhile
simultaneouslypressingauto-lock
buttonandneedleup/downbutton.
2. TheLEDdisplay
willindicate“
1”.
3. Pressthe
MODEkey
to
enterthe
self-diagnosticmode.