Table 5.1 Alarms of the machine and troubleshooting
ALARM
CODE
SHORT DESCRIPTION USER
DESCRIPTION
USER
ACTION 1
USER
ACTION 2
USER
CAUSE1
USER
CAUSE2
61 ALARM_PWM_INVERTE
R
STARTUP TEST
ERROR
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
ANOMALY IN THE
POWER INVERTER
CONTROL
BOARFD
FAULT
62 ALARM_V_POWER_MOT
OR
CONTROL BOARD
FAULT
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
ANOMALY IN THE
MOTOR DRIVER
FAULT
CONTROL
BOARFD
FAULT
63 ALARM_PWM_MOTOR CONTROL BOARD
FAULT
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
ANOMALY IN THE
MOTOR DRIVER
FAULT
CONTROL
BOARFD
FAULT
67 ALLARM TABLE
CALIBRATION
CALIBRATION
ERROR
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
71 ALARM_CTE THERMAL 2T/4T
ERROR
WAIT COOLING
THE POWER
STAGE A FEW OF
MINUTES
OUT OF LIMIT OF
THE MACHINE
WORKING
72 ALARM_MOTOR_SPEED MOTOR SPEED
ERROR
CHECK TORCH
CONSUMABLE
PARTS,
PRESSURE OF
THE ROLLS
TORCH QUALITY BAD MOTOR
FIXING ROOLS
73 ALARM_MOTOR_ENCOD
ER
MOTOR SPEED
ERROR
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
FAULT OF THE
CONTROL BOARD
FAULT OF THE
SPEED
SENSOR
76 ALARM_MOTOR_BRAKE MOTOR BRAKE
ERROR
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
FAULT CONTROL
BOARD
77 ALARM MOTOR
CURRENT
MOTOR ERROR WAIT ALARM
RESET
POWER OFF /
POWER ON
CONTACT THE
SERVICE
CENTER
TOO STRONG
FIXING ROOLS
BAD QUALITY
OF THE TORCH
80 ALARM DITER STOP CONTROL BOARD
FAULT / CLOUD
CONNECTION
BOARD FAULT
FOR EVOLVE 200
PRESS THE
RIGHT UPPER
BUTTON TO
RESET THE
ALARM
CONTACT THE
SERVICE
CENTER
FAULT CONTROL
BOARD
FAULT CLOUD
CONNECTION
BOARD