Page 17 of 97
2-SAFETY INFORMATION
______________________________________________________________________________________________
The dangerous zone is determined by the field of action of the crane.
It is absolutely forbidden to stay under hanging loads
There could be further dangers in the working area: please, observe the following rules
Don’t work near electric wires, danger of death in case of contact
with electric wires. While working, keep the following minimum
distance from the power line:
Voltage (KV) Min dist. Insulated electric wire (m)
<1 3
1< Un <= 30 3.5
30< Un <= 132 5
> 132 7
2.5 Emergency stop
Note: This procedure can be performed in any moment.
In compliance with the safety rules in force, the machine has been provided with emergency devices.
They must be operated to reduce the stopping time when the usual stop procedure would not enable
actual or impending danger to the operator or to the machine itself to be averted.
CAUTION!!!
Before putting the machine back into service, remove the cause of danger.
Location of emergency devices
The machine has been provided with several types of emergency devices.
• Emergency push-button - located on main switchboard
• Emergency push-button - located on radio remote control
About emergency devices
The main features of the installed emergency devices are:
Mushroom-shaped emergency push-button;
PUSH the mushroom-shaped button to stop the machine.
Machine back into service after emergency
In order to avoid unintended start-up, the emergency state remains active until the machine is put
into service.
To put the machine back into service:
Note: Before putting the machine back into service, remove the cause of danger.
→ Find out the push button used to activate the emergency state;