25
g) Replace the countercover (7).
h) Close cover (8), rising and tighten latch (9).
If the counterknife (1) is worn, with the edge rounded,
invert it to use the other side.
a) Remove the feeding chute according item “a” of
previous page.
b) Remove the nuts (2) and then the counterknife (1).
c) Install the new counterknife in position according
illustrated below.
d) Reinstall the feeding chute.
NOTE: The counterknife with rounded edge cause
misinform cutting, product shredding and power waste.
Thereafter the counterknife assembly check the play
between the knives and impeller, according described
on previous item.
7.4- Counter knife replacement
7
1
8
9
2
1
OPERATION TECHNICAL MANUAL - MILL JF 2D
English