Electrical System
9.16
3507, 3508, 3509, 3512, 3513, 4007, 4008, 4009, 4012, 4013
9.5.7 Cab Harness - Platform Machines Only (Continued)
20
1617 14
12
15
VENTIL
ERS LIFT DOWN
VENTIL
ERS LIFT UP
PUMP
VENTIL
ERS TELESCOPE IN
VENTIL
ERS TELESCOPE OUT
M
ERS ELECTRIC
-
BATTERY
+
201617 14
12
15
RELAY
ERS PUMP POWER
14 12
20
1617 15
ERS GROUND CMD
FUSE
SWITCH
8
3
2
4
5
7
1
LED
ERS ENABLING
ENABLING
SWITCH LIFT
ERS LIGHTED
FROM SCHEME 004
30
33
29
21
27
6
RELAY
ENABLING
ERS PUMP
30
87a
87
85
86
SWITCH TELESCOPE
ERS LIGHTED
9
ERS
7
7
1234
4523
1
87 651
12 12 2121 21
-+ +---++ +-
33
57
12
14
16
17
15
56
61
62
63
64
57
66
65
67
68
70
69
33
33
17
16
15
14
12
56
8
7
10
9
57
10
-+
12
30
30
MZ1850
LSS ALARM SIGNAL -BK 12
LIFT DN ERS -BK 14
LSS POWER BY ERS GROUND CMD -BK 20
LIFT UP ERS -BK 15
TELE OUT ERS -BK 16
TELE IN ERS -BK 17
X102
M100
VENTIL
DU MP VA LVE
X114
Y100 A
Y100 B
Y101 A
Y101 B
K112
X103
D106.9
D106.1 D106.4D106.3D106.2 D106.8
Y102
D106.11 D106.12D106.10
D106.6D106.7 D106.5
F102 (10A)
H110
LED
OVERLOAD
E101
WARNING
BUZZER
S105
H113
S106
H111
CABIN ELECTRICAL BOX
X111
ERS GROUND CMD BOX
K113
H114
S107
D105.7
X120
X119
X128
X126
X126
X127X127
X129 X130 X131 X132 X133
P->B P->A P->A P->B
X135
X135
X135
X135
35 mm^ 235 mm^ 2
35 mm^ 2
PRESSURE LIMITING
VALV E
(AUSTRALIAN ONLY)
X140
(POWER FOR MAX PRESSURE)
1.5 mm^ 2
1.5 mm^ 2
X141
X142
1.5 mm^ 2
Y103
1.5 mm^ 2
ON
UP
OFF
DOWN
OUT
IN
Courtesy of Crane.Market