106
Trouble shooting
Operator’s Manual QUADRIGA 1000/BB
“Hint 16”
“Wrong AWP SerNum”
“Hint 17”
“High Vert Stress”
“Error 101”
“EEPROM not valid”
“Error 102”
“QPower linkdown”
“Error 103”
“QIntface linkdwn”
“Error 201”
“LowerBB Motion”
“Error 202”
“LowBB WrongDir”
“Error 203”
“UpperBB Motion”
“Error”
“Hint 16”
“Wrong AWP SerNum”
“AWP Laser Sensor Serial Number not valid”
Call the Technical Assistance Service.
“Hint 17”
“High Vert Stress“
“Excessive bead extraction force”
The message appears after the fifth consecutive
interruption. The blocked tool must be rearmed with the
lever. Check the conditions of the tyre and press the
MANUAL MODE key to continue.
A list of the ERRORS shown on the Display:
“Error 101”
“EEPROM not valid”
“The Eprom data is not valid”
This error may be displayed only at machine start up if
the software detects an error in the saved data or if the
data is absent; (Call the Technical Assistance Service).
“Error 102”
“QPower linkdown”
“Communication with motor control failed”
There is a communication failure with the Motor Control
Card; (Call the Technical Assistance Service).
“Error 103”
“QIntface linkdwn”
“Communication with solenoid valve control failed”
There is a communication failure with the Solenoid Valve
Interface Card; (Call the Technical Assistance Service).
“Error 201”
“LowerBB Motion”
“Lower Bead Breaker Operation”
In automatic procedures, this error may be displayed
when the lower bead breaker starts but does not move,
or does not move smoothly; (Call the Technical
Assistance Service).
“Error 202”
“LowBB WrongDir”
“Lower Bead Breaker Wrong Direction”
This error may be displayed when the lower bead
breaker is activated but moves in the opposite direction
to the required one; (Call the Technical Assistance
Service).
“Error 203”
“UpperBB Motion”
“Upper Bead Breaker Operation”
In automatic procedures, this error may be displayed
when the upper bead breaker starts but does not move,
or does not move smoothly; (Call the Technical
Assistance Service).