Chapter 4  ADJUST MENU SETTINGS 
4.11  MAINTENANCE 
4-75 
4 
 NSTALLATION MANUAL
When "Yes" is selected, the scanner time stored in the scanner internal control circuit 
is transferred to the display unit to be stored. 
 
Target scanner 
  NKE-2103 
 Display Unit to Scanner 
Restores the scanner time data stored in the display unit into the scanner internal control 
circuit. 
When replacing the scanner internal control circuit, perform the procedure below to 
inherit scanner time data. 
1. Save the scanner time data. 
2. Replace the scanner internal control circuit 
3. Restore the scanner time data. 
 
1  Open  Maintenance  - Display Unit to Scanner . 
 
 Yes   :  Transfers the scanner time data to the scanner internal control 
circuit. 
 No   :  Does not transfer. 
 
When "Yes" is selected, the scanner time saved in the display unit is transferred to 
the scanner internal control circuit to be restored. 
 
Target scanner 
  NKE-2103