35
9 Adjustment options
9.4 Parameter level
Action Function Display
(Example)
Possible
setting
with keys
➩
"Detailed expla-
nations", page
38ff.
> 1
second
Reset the stored
minimum
pressure
reset
> 2
seconds
➩
"Peak-reading
pointer", page 38.
> 1
second
Reset the stored
maximum
pressure
reset
> 2
seconds
➩
"Peak-reading
pointer", page 38.
> 1
second
Display and set
density
correction
0.100—5.000
➩
"Densitiy cor-
rection", page 40.
> 1
second
Display and set
dimensional unit
of pressure
mbar
bar
psi
mmHg
mmH
2
0
ftH
2
0
inHg
inH
2
0
mH
2
0
MPa
Torr
kPa
kgcm
2
➩
"Dimensional
unit", page 38.
> 1
second
Display or set
output current at
measurement
start (with
pressure input)
3.85—
21.50mA
➩
"Output current,
measurement
start and end",
page 38.
4mA
> 2
seconds
> 1
second
Display or set
output current at
measurement
end (with
pressure input)
3.85—
21.50mA
➩
"Output current,
measurement
start and end",
page 38.
20mA
> 2
seconds
> 1
second
Display or set
damping
(time constant)
0.0—100.0sec
➩
"Damping",
page 38.
+
+