EasyManuals Logo
Home>Juniper>Network Router>E Series

Juniper E Series User Manual

Juniper E Series
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #126 background imageLoading...
Page #126 background image
E-series Hardware Guide
108 ! Double-Bit Errors on SRP Modules
If depressing the software reset button fails to correct the issue with the line
module, depress the board reset button. This action reboots the line module.
The buttons work in the same way for the SRP module. Depressing the board reset
button on an SRP module is equivalent to rebooting the E-series router and causes
all the line modules to reboot.
Double-Bit Errors on SRP Modules
SRP modules include error checking and correction (ECC) to protect their SDRAM.
ECC provides error detection of single-bit and double-bit errors and correction of
single-bit errors for the SDRAM as follows:
! If ECC detects a single-bit error, it automatically corrects the error, and
operation continues.
! If ECC detects a double-bit error, it logs the error, stops the main processor on
the controller, and takes the SRP module offline.
Detecting Double-Bit Errors
The following message appears on the console if ECC detects a double-bit error:
ALERT 05/10/2000 13:10:33 os: failed: ECC DOUBLE BIT ERROR OCCURRED
Address = 0xe95db10
Data (Upper 32Bits) = 0xe95db20
Data (Lower 32Bits) = 0x55d06c
ECC Data Bits = 0x2b
ECC 1Bit Error Counter = 0x0
*** YOU MUST PERFORM A HARD RESET TO CONTINUE ***
ALERT 05/10/2000 13:10:34 os: PROCESSOR EXCEPTION: 0x200n
If ECC detects a double-bit error in a system that contains a redundant SRP module,
the redundant module becomes active and the system continues to operate.
However, you must still troubleshoot the SRP module with the double-bit error. If
ECC detects a double-bit error in a system that does not contain a redundant SRP
module, you must troubleshoot the SRP module immediately. See Fixing Double-Bit
Errors.
Fixing Double-Bit Errors
To fix a double-bit error:
1. Remove the second SRP module, if there is one.
2. Reboot the system with the board reset button on the primary SRP module (see
Figure 12).
These actions attempt to correct a transient double-bit error. However, if the console
displays a memory test failure for the SRP module after you reboot, or if the FAIL
LED on the SRP module stays on during rebooting, the SDRAM is permanently
damaged and needs replacing. In this event, call Juniper Networks Customer
Service to arrange for repair.

Table of Contents

Other manuals for Juniper E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper E Series and is the answer not in the manual?

Juniper E Series Specifications

General IconGeneral
BrandJuniper
ModelE Series
CategoryNetwork Router
LanguageEnglish

Related product manuals