Table 42: Chassis Component Alarm Condions on EX4100 and EX4100-F Switches
(Connued)
Chassis
Component
Alarm Condion Alarm Severity Remedy
An unknown power
supply is installed.
Major Install a power supply recommended by
Juniper Networks.
A mix of power
supplies with dierent
airow direcons is
installed.
Major Do not mix power supplies with dierent
airow direcons in the same chassis.
A mix of fan modules
and power supplies
with dierent airow
direcons is installed.
Major Do not mix fan modules and power supplies
with dierent airow direcons in the same
chassis.
Fan module A fan module is not
installed.
Major Install the fan module.
A fan module has
failed.
Major Replace the fan module.
A mix of fan modules
with dierent airow
direcons is installed.
Major Do not mix fan modules with dierent
airow direcons in the same chassis.
A mix of fan modules
and power supplies
with dierent airow
direcons is installed.
Major Do not mix fan modules and power supplies
with dierent airow direcons in the same
chassis.