Table 11: Airow Direcon in EX4100 and EX4100-F Switch Models
(Connued)
Model Number Fan Modules and Power
Supply
Direcon of Airow
EX4100-F-24P
EX4100-F-48P
Two built-in fans with AFO
cooling.
Front-to-back—cold air to
cool the chassis enters
through the vents on the
front panel of the chassis,
and hot air exits through
the vents on the rear panel
of the chassis.
EX4100-48T-AFI The switch ships with two
fan modules and an AC
power supply, each with a
label AIR IN and a Juniper
Azure Blue handle.
Back-to-front—cold air to
cool the chassis enters
through the vents on the
rear panel of the chassis,
and hot air exits through
the vents on the front panel
of the chassis.
CAUTION: Do not mix:
Power supplies with dierent airow direcons in the same chassis.
Fan modules with dierent airow direcons in the same chassis.
Power supplies and fan modules with dierent airow direcons in the same chassis.
If you install power supplies or fan modules with dierent airow direcons, Junos OS
raises an alarm.
Under normal operang condions, the fan modules operate at a moderate speed.
Temperature sensors in the chassis monitor the temperature within the chassis.
If a fan module fails, or if the ambient temperature inside the chassis rises above the
acceptable range, Junos OS raises an alarm. If the temperature inside the chassis rises
above the threshold temperature, the system shuts down automacally.
56

Table of Contents

Other manuals for Juniper EX4100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4100 and is the answer not in the manual?

Juniper EX4100 Specifications

General IconGeneral
ModelEX4100
CategorySwitch
LayerLayer 2/3
Power ConsumptionVaries by model and configuration
PoEOptional
ManagementWeb UI, CLI, SNMP
Operating Temperature0°C to 45°C
Input Voltage100-240V AC
Storage Temperature-40°C to 70°C
Humidity5% to 90% non-condensing
DC Power Input-48V DC
JUNOS OSYes
Security FeaturesACLs
Layer 2 FeaturesVLAN, RSTP, MSTP, LACP
Layer 3 FeaturesStatic routing, OSPF
QoS8 queues per port