Page #64 background imageLoading...
Page #64 background image
If the switch is operaonal while you are replacing fan modules, you must remove only one fan module
at a me. The switch connues to operate for 60 seconds without thermal shutdown while you are
replacing a fan module.
Airow Direcon in EX4100 and EX4100-F Switch Models
Table 11 on page 55 shows the direcon of airow in EX4100 and EX4100-F models as shipped.
Table 11: Airow Direcon in EX4100 and EX4100-F Switch Models
Model Number Fan Modules and Power
Supply
Direcon of Airow
EX4100-48P
EX4100-24P
EX4100-48MP
EX4100-24MP
EX4100-48T
EX4100-24T
The switch ships with two
fan modules and an AC
power supply, each with
the label AIR OUT and a
Juniper Gold handle.
Front-to-back—cold air to
cool the chassis enters
through the vents on the
front panel of the chassis,
and hot air exits through
the vents on the rear panel
of the chassis.
EX4100-48T-DC
EX4100-24T-DC
The switch ships with two
fan modules and a DC
power supply, each with a
label AIR OUT and a
Juniper Gold handle.
Front-to-back—cold air to
cool the chassis enters
through the vents on the
front panel of the chassis,
and hot air exits through
the vents on the rear panel
of the chassis.
EX4100-F-24T
EX4100-F-48T
One built-in fan with AFO
cooling.
Front-to-back—cold air to
cool the chassis enters
through the vents on the
front panel of the chassis,
and hot air exits through
the vents on the rear panel
of the chassis.
55

Table of Contents

Other manuals for Juniper EX4100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4100 and is the answer not in the manual?

Juniper EX4100 Specifications

General IconGeneral
ModelEX4100
CategorySwitch
LayerLayer 2/3
Power ConsumptionVaries by model and configuration
PoEOptional
ManagementWeb UI, CLI, SNMP
Operating Temperature0°C to 45°C
Input Voltage100-240V AC
Storage Temperature-40°C to 70°C
Humidity5% to 90% non-condensing
DC Power Input-48V DC
JUNOS OSYes
Security FeaturesACLs
Layer 2 FeaturesVLAN, RSTP, MSTP, LACP
Layer 3 FeaturesStatic routing, OSPF
QoS8 queues per port