SRX345 Services Gateway Clearance Requirements for Airflow and Hardware
Maintenance
When planning the installation site for the SRX345 Services Gateway, you need to allow
sufficient clearance around the device. Consider the following:
For the operating temperature of the services gateway to be optimal, the airflow around
the chassis must be unrestricted. The fan tray contains four fans and provides
front-to-back chassis cooling.
For service personnel to remove and install hardware components, there must be
adequate space at the front and back of the device. Allow at least 24 in. (61 cm) both
in front of and behind the device.
If you are mounting the device in a rack with other equipment, or if you are placing it
on the desktop near other equipment, ensure that the exhaust from other equipment
does not blow into the intake vents of the chassis.
For information on the airflow through the SRX345 Services Gateway chassis, see
“Understanding the SRX345 Services Gateway Cooling System” on page 13.
Related
Documentation
SRX345 Services Gateway Rack-Mounting Requirements and Warnings on page 25
SRX345 Services Gateway Rack Size and Strength Requirements on page 29
SRX345 Services Gateway Spacing of Mounting Brackets and Flange Holes on page 29
Copyright © 2017, Juniper Networks, Inc.30
SRX345 Services Gateway Hardware Guide

Table of Contents

Other manuals for Juniper SRX345

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper SRX345 and is the answer not in the manual?

Juniper SRX345 Specifications

General IconGeneral
USB 2.0 ports quantity1
Ethernet LAN (RJ-45) ports8
Flash memory8000 MB
Internal memory4000 MB
CertificationFCC A, RoHS 2
Rack capacity1U
Heat dissipation420 BTU/h
Power consumption (typical)122 W
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 90 %
Routing protocolsBGP, CLNS, MPLS, OSPF, RIP-1, RIP-2
Supported network protocolsIPv4, IPv6
Firewall securityYes
Security algorithmsIPSEC, SSL/TLS
Networking standardsIEEE 802.1p
Ethernet LAN data rates10, 100, 1000 Mbit/s
Weight and Dimensions IconWeight and Dimensions
Weight4900 g
Dimensions (WxDxH)440.9 x 370.1 x 43.6 mm